September 08, 2022

What is an NFPA 25 Fire Inspection in New York?

The National Fire Protection Association Standard# 25, otherwise known as NFPA 25, is the nationwide standard that governs the inspection, testing, and maintenance of water-based fire protection systems. Created in 1992, NFPA 25 has continued to evolve, with ever-improving criteria and guidelines regarding evaluation techniques pertaining to fire sprinkler inspections, fire pump flow tests, and all items applicable toward water-based fire protection systems. This standard was created in order to help all building owners comply with laws, codes, and regulations in an effort to keep the public safe in the event of a fire. The NFPA 25 testing and inspection regimen performed in accordance with New York City requirements ensures maximum system integrity to avoid failure, provide specific methods to ensure code enforcement and ensure fast, effective response in a fire emergency.
The NFPA 25 regimen mandated by New York City includes specific annual, monthly, quarterly, weekly, and (in some cases) a daily schedule of items to be performed. These items include information relative to the conditions of the system's water supply, gravity and pressure tanks, valves, risers, piping, sprinkler heads, fire department connections, and alarms.
These items include information on the conditions of and documentation about the elements of your system, including, but not limited to, the following:

  • Water Supply & Temperature Control
  • Gauges
  • Gravity, Heating Systems, & Pressure Tanks
  • Valves
  • Risers
  • Piping
  • Limit Switches
  • Sprinkler Heads & Discharge Devices
  • Fire Department Connections
  • Alarms
  • Fire/Booster/Special Service Pumps
  • Hangers, Braces, and Supports
  • Expansion Joints/Hoops & Grillage
  • Drainage Testing/Manual Release/Strainers
  • Internal Obstructions
  • Flow Testing
  • Corrosion & Damage
  • Conditions of all other System Equipment & Accessories
Allstate Sprinkler's inspection and service personnel have all been certified by the FDNY. We are uniquely qualified to help you meet the requirements for the necessary S-12 Certificate of Fitness. We have customized computer software to verify and ensure that your facility complies with all required codes and make certain that any potential liability and fines for non-compliance to NFPA 25 are mitigated.

Contact us immediately to complete the appropriate paperwork and contracts to satisfy the FDNY's requirements and to ensure compliance with all local ordinances. We are fully knowledgeable of the NFPA 25 Fire Sprinkler Inspection regimen now mandated by the New York City Fire Department and we are fully prepared to assist you.

About Allstate Sprinkler

Our family business has developed from a "mom and pop" company into a highly regarded fire protection contractor servicing the New York City Metropolitan area. Our commitment is to assist you with all of your commercial and residential fire protection needs. We have built a reputation on the sound principle of providing professional service and high-quality products to all our customers. Our services include but are not limited to the following: complete installations and alterations of fire sprinkler and standpipe systems, prompt correction of all fire department violations, five-year hydrostatic pressure tests, emergency service, and repairs, fire pump testing and installations, fire extinguisher sales, and service, and all fire safety products and equipment.

Allstate Sprinkler, LLC is a licensed Master Fire sprinkler contractor with the New York City building department. Providing our customers with cost-effective, professional, and reliable service is our priority. We hope that you will enjoy our website and become a part of our family customer base.